Ulp 8040 Industrial Reverse Osmosis Membrane for Pure Water High Salt Rejection 8040 Water Reverse Osmosis Membrane Systems Commercial RO Membrane
MAIN PRODUCTS The product specification Operating Limit: When PH is above 10, the Maximum Temperature of Continuous Oper;
Basic Info
Model NO. | ULP 4040 Industrial Reverse Osmosis Membrane for P |
Test Pressure | 150psi |
Recovery Rate | 15% |
Application | Industrial & Commercial Water Purifier |
Marketing Type | Ordinary Product |
Video Outgoing-Inspection | Provided |
Working Pressure | 150psi-600psi |
After-Sales Service Provided | Video Technical Support, Online Support |
Specification | BW-8040-ULP |
Trademark | Hynamo/OEM/ODM |
Origin | Hangzhou City, Zhejiang, China |
HS Code | 8421991000 |
Production Capacity | 14000PCS/Day |
Product Description
MAIN PRODUCTSThe product specification
TYPE | Production Flow Rate GPD(m³/d) | Stable Rejection Rate | Operation Pressure | Recovery Rate |
4040-LP | 2400(9.1) | 99.5% | 225 psi (15bar) | 15% |
4040-ULP | 2400(9.1) | 99.2% | 150 psi (10bar) | 15% |
4040-XLP | 2400(9.1) | 98.5% | 100 psi (7bar) | 15% |
8040-LP | 10500(40) | 99.5% | 225 psi (15bar) | 15% |
8040-ULP | 10500(40) | 99.2% | 150 psi (10bar) | 15% |
8040-XLP | 10500(40) | 98.5% | 100 psi (7bar) | 15% |
LP(Low Pressure) | ULP(Ultra Low Pressure) | XLP(Extra Low Pressure) | |
Test Conditions | 2000 ppm Nacl Solution 225 psi Applied Pressure 77F (25ºC)Operation Temperature 15% Pemeate Recovery 6.5-7.5 PH Range | 1500 ppm Nacl Solution 150 psi Applied Pressure 77F (25ºC)Operation Temperature 15% Pemeate Recovery 6.5-7.5 PH Range | 1500 ppm Nacl Solution 100 psi Applied Pressure 77F (25ºC)Operation Temperature 15% Pemeate Recovery 6.5-7.5 PH Range |
Type | Configuration: Low Pressure Spiral Membrane Polymer: Composite polyamide Membrane O Ring: EPDM |
Operating Limit:
Maximum Operating Temperature | 113ºF(45ºC) |
Maximum Working Pressure | 600psi(41.0 bar) |
The high pressure drop | 15psi (1.0bar) |
Continuously operating PH range a | 3-10 |
Short wash PH range (30min) b | 2-12 |
Maximum feed water SDI | SDI 5 |
Tolerance Of Free Chlorine | <0.1ppm |
Maximum pressure drop for single membrane element | 15psi(0.1Mpa) |
- When PH is above 10, the Maximum Temperature of Continuous Operation is 35ºC.
- Under certain conditions, the presence of free chlorine and other oxidants in the water may cause serious membrane damage, which doesn't belong to product warranty range.
FAQ
Q: Your company is manufacturer or trading company?
A: Yes, we are a manufacturer, we have our own factory and meanwhile we cooperate with other factories with our own technology. Haiana has an 18-year background in the reverse osmosis membrane industry with independent R & D personnel and engineering and mastered the core technology of high salt water purification.
Q: How many employees does your company have?
A: Hynamo headquarters has more than ten people, 242 workers in the factory, and 45 office workers. We are still a small company, and our goal is not to be the biggest but to be stronger. In the segmented high desalination market, product quality and service are maximized.
Q: What are the advantages of your company and products?
A: Hynamo technical advantage lies in the high desalination technology, and the process of coating polyamide is different from its counterparts. Therefore, the use of household membranes, according to market feedback, can be applied to 3,000-6,000 ppm water quality. Seawater membranes can be applied in an environment of 30,000-40,000ppm, and the cost advantage is very obvious.
Q: if quality problem, what are your guarantee terms?
A: At present, we maintain zero customer complaints about products. Please note that the first item of our company's values: Do not let customers count one copper coin. If there is a quality problem, we will guarantee the replacement and be responsible for the freight on the way according to a reasonable quality problem verification process.
Q: What is your MOQ?
A: Our minimum order quantity varies from model to model. There are also differences in OEM orders. The minimum order for the household membrane is 100 (two boxes), and the minimum for the industrial membrane is five pieces. If there is an industrial membrane for refueling household
Q: How to pay?
A: TT and L/C are acceptable and TT will be more appreciated. 30% deposit before producing, 70% balance against the copy of B/L.
Q: What is the delivery time?
A: Usually within 15 days. Also depends on order quantities.
Q: Can the package be customized with our own logo?
A: Yes, the package can be customized with your logo, but the MOQ will be higher which we can discuss as per the specific orders.
Q: How to install it after the products arriving the destination?
A: We will provide detailed illustrations to you. And we can also provide a guide to your workers on how to use it and how to maintainit.
Q: What certification do you have?
A: We have NSF, ISO9001, OHSAS18001, and ISO14001 Certifications.
Fore more details, welcome to contact us
Contact person: Nancy
You may also like
Send inquiry
Send now